Glucose Hexokinase FS
Measurement of glucose concentration in serum or plasma is mainly used in the diagnosis and monitoring of the therapy of diabetes mellitus.
Other applications are for the detection of neonatal hypoglycemia, pancreatic islet cell carcinoma and the evaluation of carbohydrate metabolism in various diseases.
- Diabetes mellitus
- Advanced age – onset (Adult)
- Age of growth – onset (Teenager)
- Pancreatitis
- Endocrine disorders, eg. acromegaly, Cushing's syndrome, thyrotoxicosis, pheochromohyperaldosteronism
- Drugs, eg. steroids, thiazides, oral contraceptives
- Chronic kidney failure
- Emphasize
- I.V. glucose infusion
- Postprandial
- Insulinoma
- Adrenal cortex insufficiency
- Hypopituitarism
- Extra – pancreatic neoplasm
- Severe liver disease
- Alcohol consumption
- Drugs, eg. sulfonylureas, salicylates, phenformin, insulin, etc.
Proline Glucose Hexokinase FS comes in a liquid format which provides convenience for users as no reconstitution is required which helps reduce the risk of misdiagnosis.
Proline Glucose Hexokinase FS reagent is suitable for various third-party analyzers such as Abbott, Advia, Cobas, Hitachi, Olympus, Response, TokyoBoeki, and Beckman Coulter. Please contact our technical support at marketing@proline.co.id for further compatibility information on other types of analyzers.
- Enzymatic UV test using hexokinase
- No interference: ascorbic acid 30mg/dL, bilirubin 60mg/dL, hemoglobin 500mg/dL and lipemia up to 1800mg/dL triglycerides
- Measurement linearity reached 500 mg/dL, with a lower limit of detection of 2 mg/dL
No. Catalog | R1 | R2 | Kit Size |
1 2511 99 10 022 | 5 X 20 mL | 1 X 25 mL | Multi Purpose Kit |
1 2511 99 10 025 | 3 X 80 mL | 1 X 60 mL | Multi Purpose Kit |
1 2511 99 10 027 | 2 X 100 mL | 2 X 25 mL | Multi Purpose Kit |
1 2511 99 10 029 | 3 X 200 mL | 1 X 150 mL | Multi Purpose Kit |
1 2511 99 10 181 | 4 X 36 mL | 4 X 9 mL | TMS50i |
1 2511 99 10 191 | 4 X 36 mL | 4 X 9 mL | TMS24i |
1 2511 99 10 591 | 4 X 60 mL | 4 X 15 mL | Mindray |
1 2511 99 10 914 | 6 X 60 mL | 6 X 15 mL | Hitachi 917 |
1 2511 99 10 920 | 4 X 38 mL | 4 X 11 mL | Proline® R-910 |
1 2511 99 10 951 | 6 X 36 mL | 6 X 9 mL | Advia |
1 2511 99 10 965 | 6 X 25 mL | 6 X 6 mL | Other Automated Instrument |
Adult (Fasting) | ||
Plasma venous | 70 – 115 mg/dL | 3.9 – 6.4 mmol/L |
Blood | 70 – 100 mg/dL | 3.9 – 5.6 mmol/L |
Newborn | ||
Umbilical cord blood | 63 – 158 mg/dL | 3.5 – 8.8 mmol/L |
1 hour | 36 – 99 mg/dL | 2.0 – 5.5 mmol/L |
2 hours | 36 – 89 mg/dL | 2.2 – 4.9 mmol/L |
5 – 14 hours | 34 – 77 mg/dL | 1.9 – 4.3 mmol/L |
10 – 28 hours | 46 – 81 mg/dL | 2.6 – 4.5 mmol/L |
44 – 52 jam | 48 – 79 mg/dL | 2.7 – 4.4 mmol/L |
Children and teenager (fasting) | ||
1 – 6 year(s) | 74 – 127 mg/dL | 4.1 – 7.0 mmol/L |
7 – 19 years | 70 – 106 mg/dL | 3.9 – 5.9 mmol/L |
Each laboratory should check if the reference ranges are transferable to its own patient population and determine its own reference ranges if necessary
- Thomas L. Clinical Laboratory Diagnostics. 1 ed. Frankfurt: TH-Books Verlagsgesellschaft; 1998. p. 131-7."
- Sacks DB. Carbohydrates. In: Burtis CA, Ashwood ER, editors. Tietz Textbook rd of Clinical Chemistry. 3 ed. Philadelphia: W.B Saunders Company; 1999. p. 750-808.
- Guder WG, Zawta B et al. The Quality of Diagnostic Samples. 1 ed. Darmstadt: GIT Verlag; 2001; p. 30-1.
- Sacks DB, Bruns DE, Goldstein DE, Mac Laren NK, Mc Donald JM, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2002; 48: 436-72.
- Young DS. Effects of Drugs on Clinical Laboratory Tests. 5th ed. Volume 1 and 2. Washington, DC: The American Association for Clinical Chemistry Press 2000.on. ClinChemLabMed 2007;45(9):1240-1243.
- Bakker AJ, Mücke M. Gammopathy interference in clinical chemistry assays: mechanisms, detection and prevention. ClinChemLabMed 2007;45(9):1240-1243.
- Diabetes
Reach out to our team for more product and orders information.
- Phone. +6221 8984 2722
- WhatsApp. +62 815 1359 2626
- Email. marketing@proline.co.id
Contact our Technical Assistance team for further assistance with product specifications, services and other technical documents.
- Phone. +6221 8984 2722
- WhatsApp. +62 817 9324 884
- Email. technical.support@prodis.co.id