ASAT (GOT) FS (IFCC mod.)

Product Number: 1 2601

Description

Alanine Aminotransferase (ALAT/ALT), formerly called Glutamic Pyruvic Transaminase (GPT), and Aspartate Aminotransferase (ASAT/AST), formerly called Glutamic Oxalacetic Transaminase (GOT), are the most important representatives of a group of enzymes, the amino-transferases or transaminases, which catalyze the conversion of a-keto acids into amino acids by transfer of amino groups.

As a liver-specific enzyme, ALAT is only significantly elevated in hepatobiliary diseases. Increased ASAT levels, however, can occur in connection with damages of heart or skeletal muscle as well as of liver parenchyma. Parallel measurement of ALAT and ASAT is, therefore, applied to distinguish liver from heart or skeletal muscle damages. The ASAT/ALAT ratio is used for differential diagnosis in liver diseases. While ratios < 1 indicate mild liver damage, ratios > 1 are associated with severe, often chronic liver diseases.

Increased in

  • Hepatocellular destruction, (example: viral hepatitis, Liver Shock, alcoholic hepatitis)
  • Myocardial Infarction
  • Hemolysis in vivo
  • Musculoskeletal disease
  • Lung Infarction
  • Post-hepatic obstructive bile duct disease

Decreased in

  • End stage liver disease
  • Renal hemodialysis and/or renal insufficiency

Features

Ready to use reagent.

Proline ASAT (GOT) FS (IFCC mod.) comes in a liquid format which provides convenience for users as no reconstitution is required which helps reduce the risk of misdiagnosis.

Open system reagent, compatible with a wide range of instruments.

Proline ASAT (GOT) FS (IFCC mod.) reagent is suitable for various third party analyzers such as Abbott, Advia, Cobas, Hitachi, Olympus, Response, TokyoBoeki, and Beckman Coulter. Please contact our technical support at marketing@proline.co.id for further compatibility information on other types of analyzers.

Specification

  • Optimal UV Test according to IFCC (International Federation of Clinical Chemistry and Laboratory Medicine)
  • No interference: ascorbic acid 30mg/dL, bilirubin 60mg/dL, hemoglobin 20mg/dL, and lipemia 1000mg/dL.
  • Measurement linearity is up to 675 U/L, with a lower limit of detection of 2 U/L

Calibrator

Control

Kit Lines

No. Catalog R1 R2 Kit Size
1 2601 99 10 022  5 X 20 mL 1 X 25 mL Multi Purpose Kit
1 2601 99 10 025 3 X 80 mL 1 X 60 mL Multi Purpose Kit
1 2601 99 10 027 2 X 100 mL 2 X 25 mL Multi Purpose Kit
1 2601 99 10 029 3 X 200 mL 1 X 150 mL Multi Purpose Kit
1 2601 99 10 181 4 X 36 mL 4 X 9 mL TMS50i
1 2601 99 10 191 4 X 36 mL 4 X 9 mL TMS24i
1 2601 99 10 591 4 X 60 mL 4 X 15 mL Mindray
1 2601 99 10 914 6 X 60 mL 6 X 15 mL Hitachi 917
1 2601 99 10 920 4 X 34 mL 4 X 10 mL Proline® R-910
1 2601 99 10 921 4 X 21 mL 4 X 6 mL Proline® R-910
1 2601 99 10 951 6 X 36 mL 6 X 9 mL Advia
1 2601 99 10 965 6 X 25 mL 6 X 6 mL Other Automated Instrument

Reference Range

Related Product

Category

  • Liver disease

Order information

Reach out to our team for more product and orders information.

  • Phone. +6221 8984 2722
  • WhatsApp. +62 815 1359 2626
  • Email. marketing@proline.co.id

Technical Support

Contact our Technical Assistance team for further assistance with product specifications, services and other technical documents.

  • Phone. +6221 8984 2722
  • WhatsApp. +62 817 9324 884
  • Email. technical.support@prodis.co.id
TOP