FORGOT YOUR DETAILS?

CREATE ACCOUNT

CRP U-hs FS

Product Number: 1 7045

Description

C-Reactive Protein (CRP) is an acute-phase protein, which is a protein whose concentration increases in the blood in response to inflammatory disorders (acute-phase response). In the blood of healthy people, CRP is present in low concentrations (<5 mg/L). This protein is elevated 6 hours after an acute inflammatory process associated with bacterial infection, post-operative conditions or tissue damage. Under conditions of a disease, the concentration of CRP can increase up to 500 mg/L. Measurement of CRP is an important laboratory test to detect acute infection, as well as simplify the inflammatory process in acute rheumatism and gastrointestinal diseases. Measurement of CRP shows various benefits when compared to the erythrocyte sedimentation rate (ESR) and leukocyte count. In fact, CRP is sensitive, increases occur earlier and concentration returns to range more quickly after healing.

Increased in

  • Peradangan dan cedera jaringan
  • Infeksi
  • penyakit rematik

Features

Ready to use reagent.

Proline CRP U-hs FS hadir dalam format cair yang memberikan kenyamanan bagi pengguna karena tidak diperlukan rekonstitusi yang membantu mengurangi risiko kesalahan diagnosis.

Open system reagent, compatible with a wide range of instruments.

Reagen Proline CRP U-hs FS cocok untuk berbagai penganalisis pihak ketiga seperti Abbott, Advia, Cobas, Hitachi, Olympus, Respons, TokyoBoeki, dan Beckman Coulter. Silakan hubungi dukungan teknis kami di marketing@proline.co.id untuk informasi kompatibilitas lebih lanjut tentang jenis penganalisis lainnya.

Specification

  • Particle-enhanced immunoturbidimetric test with two applications; high sensitivity and universal.
  • No interference: bilirubin 40mg/dL, hemoglobin 100mg/dL, and lipemia up to 1200mg/dL triglycerides
  • Measurement linearity reached 20 mg/L, with a lower limit of detection of 0.05 mg/L

Kit Lines

No. Katalog R1 R2 Ukuran Kit
1 7045 99 10 022 3 X 20 mL  3 X 20 mL Kit Serba Guna (MPK)
1 7045 99 10 191 4 X 16 mL  4 X 16 mL TMS24i
1 7045 99 10 591 4 X 20 mL  4 X 20 mL Advia® 1800
1 7045 99 10 914 3 X 20 mL  3 X 20 mL Hitachi 917
1 7045 99 10 920 4 X 11 mL  4 X 11 mL Proline® R-910
1 7045 99 10 921 4 X 8 mL 4 X 8 mL Proline® R-910
1 7045 99 10 951 6 X 20 mL 6 X 20 mL Mindray®
1 7045 99 10 965 6 X 11 mL 6 X 20 mL Other Automated Instrument

Reference Range

 Adult < 5 mg/L
 Baby newborn - 3 weeks < 4.1 mg/L
 Toddler and Children < 2.8 mg/L

Setiap laboratorium harus memeriksa apakah referensi rentang dapat dikalkulasikan untuk populasi pasiennya dan menentukan referensi rentang sendiri jika diperlukan.

Category

  • Inflamasi
  • Atherosclerosis

Order information

Hubungi tim kami untuk mengetahui lebih lanjut mengenai informasi produk dan pemesanan.

  • Phone. +6221 8984 2722
  • WhatsApp. +62 815 1359 2626
  • Email. marketing@proline.co.id

Technical Support

Hubungi tim bantuan Teknis kami untuk pertolongan lebih lanjut terkait spesifikasi produk, layanan, dan dokumen teknis lainnya.

  • Phone. +6221 8984 2722
  • WhatsApp. +62 817 9324 884
  • Email. technical.support@prodis.co.id